Two parts of a house nobody shows off, and the two you notice most when they fail.
Nobody shows guests their water tank. But most people in Jakarta know the feeling of running out of water, seeing it turn cloudy, or hearing a pump hum all night next to the bedroom. The septic tank is the same: out of mind until it smells or backs up.
Both sit below the ground floor and are built together with the substructure. Once the house stands, they are difficult and expensive to fix. That is why we build the underground water tank and septic tank of a house the way high-rise buildings build them, not as a simple concrete box under the carport.
In the coastal districts of North Jakarta, mains water is not always reliable. Volume can drop at certain hours, and quality can change without warning. A home built for comfort needs filtered water that practically never runs out, whatever happens to the supply outside.
The answer is a generous reserve. As a baseline, the Indonesian plumbing design standard, SNI 03-7065-2005, uses a household demand of 120 litres per occupant per day.[1] For a family of four with two live-in staff, we design for a minimum net tank volume of 6 m³. Two 1,500-litre tanks on the roof add another 3 m³, for a total reserve of 9 m³. This is roughly how long that water lasts if the mains supply stops completely:
| Use per person per day | Household use (6 people) | Underground tank only (6 m³) | With roof tanks (9 m³) |
|---|---|---|---|
| 120 litres (standard baseline) | 720 litres | 8 days | 12 days |
| 200 litres (more comfortable lifestyle) | 1,200 litres | 5 days | 7 days |
| 250 litres (luxury home, many bathrooms) | 1,500 litres | 4 days | 6 days |
The 200 and 250 litre figures are our own assumptions for homes with more bathrooms, rain showers and bathtubs, not standard values. The estimate also leaves out garden irrigation, car washing and topping up a pool, and a little water at the bottom of the tank always stays below the pump intake. If your home has needs like these, we size the tank for them.
Our underground water tanks are divided into chambers with separate jobs:
For the people living in the house, this means:
Our water tanks and septic tanks stand on piles and are cast as one with the substructure of the house. There are two main reasons, and we apply the same principle to the pipes.
Settlement. PIK sits on soft ground that keeps settling. A tank that simply rests on the soil can settle differently from the building next to it, cracking its walls or snapping pipe connections. Supported on piles and tied into the structure, the tank moves with the house. Pile depth is explained in Pile Foundations for a House in PIK.
Uplift. The water table in PIK is shallow. When the tank is empty, for example during cleaning, the groundwater around it pushes it upward, like a boat floating. So we also design the piles under the tank as tension piles that hold it down. Checking resistance to uplift is part of the Indonesian geotechnical design requirements.[2]
Pipes that don't depend on the soil. The same principle applies to the water and waste pipes under the ground floor. A house on piles barely moves, while the soil beneath its floor keeps settling and eventually leaves a void. A pipe that simply rests on the soil loses its support, sags, and its joints leak or break. So we tie the pipes under the floor to the substructure, and they stay fixed to the building even when the soil below them drops.
In our experience, we have never seen a concrete tank wall come out of the pour perfectly watertight. Fine shrinkage cracks and the joints between pours are its natural weak points. So we never rely on concrete alone. Our sequence:
The tank is also tested from inside: it is filled with water, the level is watched, and the outer faces are checked for seepage. The water level alone can't be the only measure, because temperature, evaporation and absorption by new concrete all affect the reading. The American Concrete Institute's standard for testing concrete tanks accounts for these factors too.[3] For us, checking the concrete surface directly for seepage remains the most convincing evidence.
The septic tank is built the same way: on piles, tied into the structure, and tested before backfilling. For a septic tank, watertightness works in both directions. Wastewater must not leak into the soil around the house, and groundwater must not leak in, because it fills the tank quickly and disturbs the treatment process.
Our septic tanks have three chambers:
Adding a filter stage like this is in line with the Indonesian septic tank standard, SNI 2398:2017. The standard does not allow septic tank effluent to be discharged straight into the environment, and offers a filter as one of the further-treatment options for areas with a high water table, such as PIK.[4]
In the houses we build, only toilet waste goes into the septic tank. Water from showers, basins and the kitchen runs separately to the estate's sewer main. SNI 2398:2017 calls this a separate system, and sizes the septic tank from two parts: room for the wastewater to stay in the tank for a set time, and room for the sludge that builds up until the tank is emptied.[4] The retention time gives solids the chance to settle and break down before the water leaves. For the same six-person household, we take the upper end of each range in the standard:
| Component | SNI 2398:2017 formula (separate system) | Calculation (6 people) |
|---|---|---|
| Daily toilet wastewater | 20 litres/person/day × occupants | 20 × 6 = 120 litres |
| Wastewater volume | daily wastewater × 3-day retention | 120 × 3 = 360 litres |
| Sludge volume | 40 litres/person/year × occupants × 3 years | 40 × 6 × 3 = 720 litres |
| Septic tank requirement | plus 30 cm of freeboard above the water | about 1.1 m³ + freeboard |
The standard also sets a minimum septic tank size: 0.75 m wide, 1.5 m long and 1.5 m high including freeboard, or about 1.7 m³. For a six-person home, this minimum is what governs.
On top of that come the filter chamber and the final settling chamber. We design the whole tank, including both, at a minimum of 3 m³, so the septic chamber itself still meets the SNI minimum size, with headroom if the household grows.
The calculation assumes the tank is emptied every three years. Regular emptying is part of looking after the house: without it, sludge fills the space meant for wastewater, the retention time shrinks, and the water that leaves the tank is dirtier.
Water tanks and septic tanks are often left out of quotes, then appear as extra costs after the contract is signed.[5] Before choosing a contractor, ask:
Our guide to comparing contractor quotes explains how to read a quote line by line, and Building a House in PIK, Stage by Stage covers the whole sequence from planning to handover.
If you are planning a house in PIK or North Jakarta, tell us how many people will live there and how you use water. See also why clients choose Rimba.
Start from water use per person. The Indonesian plumbing standard uses 120 litres per occupant per day for houses. For a household of six, we design for at least 6 m³ net underground, plus two 1,500-litre roof tanks. The total of 9 m³ lasts roughly 6 to 12 days depending on lifestyle, before garden and pool use.
To keep raw and filtered water apart, to clean one chamber without cutting off the house, and to give pumps and filters a dry room that is easy to service and can't be heard inside the house.
PIK sits on soft ground that keeps settling. A tank on piles, tied into the structure, moves with the house, so its walls and pipes don't crack. The piles also hold the tank down against groundwater uplift when it is empty.
No. Fine shrinkage cracks and construction joints are natural weak points. The tank has to be tested, seeping spots sealed, and tested again before the excavation is backfilled.
If only toilet waste goes in, the SNI 2398:2017 formula at the top of its ranges (20 litres per person per day, 3 days' retention, 40 litres of sludge per person per year, emptying every 3 years) gives about 1.1 m³ plus freeboard. The SNI minimum size of about 1.7 m³ governs. With the filter and final settling chambers added, we design the whole tank at a minimum of 3 m³.
A filter chamber holds media such as zeolite and palm fibre, where bacteria continue breaking down the waste, so the water that leaves is cleaner. The Indonesian septic tank standard recommends this kind of further treatment where the water table is high.
Tell us where your land is, its size, your architect or consultant (if you have one), and when you plan to start. Our team will review it and get back to you.
ContactKontak
Tell us where your land is, its size, your architect or consultant (if you have one), and when you plan to start. Our team will review it and get back to you.Ceritakan lokasi lahan, luas lahan, arsitek atau konsultan (jika ada), dan rencana waktu mulai. Tim kami akan meninjau dan menghubungi Anda.
©2026 Rimba Construction. All Rights Reserved.Hak cipta dilindungi undang-undang.
OFFICEKANTOR
PT. RIMBA BANGUN PERKASA
Galeri Niaga Mediterania E8E
Pantai Indah Kapuk
Jakarta Utara 14460
Menu
OfficeKantor
PT. RIMBA BANGUN PERKASA
Galeri Niaga Mediterania E8E
Pantai Indah Kapuk
Jakarta Utara 14460
Menu
Social MediaMedia Sosial
©2026 Rimba Construction. All Rights Reserved.Hak cipta dilindungi undang-undang.